Sign In | Join Free | My ledscreensign.com |
|
Brand Name : Daxian
Model Number : DX8516
Certification : MT 386-1995
Place of Origin : China
MOQ : One set
Price : Negotiation
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability : 15 sets per month
Delivery Time : 15 work days
Packaging Details : Wooden Case
Standard : MT 386-1995, MT 818-2009
Application : of MT 818-2009 "Flame retardant cables for coal mines"
Function : used to test the combustion characteristics
Combustor size : L1100× W900 × D525mm
External dimensions of combustion chamber : 1750 ×1100× 500mm
Load current : 0-3000A continuously adjustable
Temperature measurement range : K-type thermocouple 0-1200 ℃
Volume : 0.5m³, with exhaust device
DX8516 Mining Cable Load Combustion Testing Equipment
This testing machine is manufactured according to the standard MT 386-1995 "Test methods and determination rules for flame retardancy of flame retardant cables for coal mines", and is used to test the combustion characteristics of MT 818-2009 "Flame retardant cables for coal mines" under overload conditions.
Main parameters:
1. Combustor size: L1100× W900 × D525mm
2. External dimensions of combustion chamber: 1750 ×1100× 500mm
3. Load current: 0-3000A continuously adjustable
4. Adjustable nozzle height, nozzle angle: 90 °
5. Temperature measurement range: K-type thermocouple 0-1200 ℃
6. Temperature control meter display range: 0~999.9
7. Temperature control meter accuracy: 0.5 level
8. Timer range: 0-99.99S/m/H
9. Volume: 0.5m³, with exhaust device
10. Gas: Natural gas or synthetic methane (methane content should be above 95%)
11. Working voltage: AC 380V ± 10% 50HZ
12. Total weight: 250KG
![]() |
Mining Cable Load Combustion Testing Equipment Combustion Characteristics Of MT 818-2009 Images |